The dry bulb wet bulb and dew point temperatures are important to determine the state of humid air.
Hvac wet bulb chart.
Intersect the 2 numbers on the chart shown on the next slide that will give you the amount of superheat you need using superheat table.
Once you determine the indoor wet.
You can measure the wet bulb with a thermometer with a tiny wet sock around it.
Wet bulb temperature wbt 3.
Go to your superheat table look for your outdoor drybulb and indoor wetbulb temperature where they intersect.
The dbt and wbt of the air are measured by a special thermometer called sling thermometer.
In the case of the outdoor air there s no latent heat involved.
The more humid it is inside the higher the wb will be.
The psychrometric chart highlights seven properties of air.
A psychrometric chart contains a lot of information packed in an odd shaped graph.
Psychrometric chart is one of the chart that is commonly used in solving hvac problems.
While the unit is operating measure the dry bulb temperature at the condensing unit.
The knowledge of only two of these values is enough to determine the state of the moist air including the content of water vapor and the sensible and latent energy enthalpy in the air.
Using wet bulb return air temperature the wet bulb return air temperature method is the most accurate superheat method.
This will be your target superheat.
The wet bulb dew point and apparatus dew point are iterated using a curve fitted enhancement factor.
28 6 can make a significant difference when it is multiplied out over a large air mass.
Other properties are calculated using equations and tables from ashrae 2009 fundamentals and 2008 hvac systems and equipment.
Wet bulb is the temperature at which moisture evaporates.
Temperature of the ordinary air measured by the thermometer when it is covered by wet cloth or wick is called as the wet bulb temperature commonly referred to as wbt.
Dry bulb temperature dbt 2.
Measure and record the indoor wet bulb temperature at the evaporator coil.
The tricky part is reading at this extreme level of resolution because 28 4 vs.
The indoor wet bulb reading reflects the total heat of the air and therefore the total loading on the indoor coil both sensible and latent.
The properties of air such as wet bulb temperature dry bulb temperature dew point temperature relative humidity humidity ratio specific enthalphy and specific volume are shown on this chart.
In the chart above you can see that a 62 8 degree wet bulb mass of air contains approximately 28 4 btus per lb.
It is a reference point on a chart that allows us to know what the correct superheat a piston evaporator should have.
The temperature of the air measured by the ordinary thermometer is called as the dry bulb temperature of air commonly referred as dbt.
Equation of state is p v r t 1 bm v cm v.